V3 Homepage Features
Homepage Overview
The V3 version homepage has been optimized and includes the following core features:
1. Top Buttons
- Report History (Document Icon): View locally stored measurement history records.
- Records are saved starting from the V3 upgrade and are not uploaded to the AMOS cloud, remaining stored locally only.
- Each record is displayed as a card, including a blurred image (hardware-level frosted glass processing for privacy protection), and measurement status (success/failure).
- Delete Records: Click the trash icon in the top right corner to clear all records; this action is irreversible, so use with caution.
- Individual Deletion Not Supported: This feature will be added in future versions.
- Failed records can be re-measured: Click a failed record and confirm to reuse saved data for re-measurement.
- Settings: Adjust language, voice, shooting settings, etc. (see Software Settings for details).
2. Measurement Entry
- Measurement Frame Measurement: Use the AMOS measurement frame to simulate glasses and measure fitting parameters.
- Clip Frame Measurement: Measure fitting parameters for existing store frames.
- Icons next to the buttons distinguish between measurement frames and clip frames.
3. Video Tutorials
- Official measurement frame and clip frame tutorial videos, produced by AMOS, are located at the bottom and can be viewed by clicking.
4. Permissions and Time Correction
- Permission Reminders: iFace requires camera permissions (for shooting) and app installation permissions (for upgrades). If not granted, a pop-up will appear on the homepage.
- Time Correction: If the system time is incorrect, a prompt will appear on the homepage to correct it (go to "Settings > Time"). An incorrect time may prevent internet access.
Detailed Report Page
- Content:
- Store and Subject Information: Store name, order number, frame style, name, age, phone number (name and the last four digits of the phone number can be manually entered and are stored locally only).
- Measurement Data (unit: millimeters):
- Distance Pupil Distance (right eye, left eye)
- Near 30cm Pupil Distance (right eye, left eye)
- Pupil Height (right and left eyes; measurement frame data requires syncing to AMOS for recalculation based on the selected frame)
- Face Width (used to adjust temple spread)
- Fitting Parameters:
- Temple Length (only for measurement frame; not available for clip frame)
- Lens-Eye Distance (BVD)
- Forward Tilt Angle
- Frame Curvature
- Frame A Value (width of the left and right frames)
- Frame B Value (height of the left and right frames)
- Operations:
- Print Report: Requires a connected printer to print the full report.
- Sync Data: Upload data to AMOS for recalculation based on the user's selected frame parameters.
- AI Indicator: A triangular AI icon in the top left corner of the report indicates that the results were generated by AI calculations.